CyberArk Sentry – Privileged Cloud — Question 91
What is determined by the “MaxConcurrentConnections” setting within a platform?
Answer options
- A. maximum number of concurrent connections allowed between the CPM and target machine for password replacement
- B. maximum number of concurrent connections allowed between the PSM and remote machines
- C. maximum number of concurrent connections allowed for a specific account on the platform through the PSM
- D. maximum number of concurrent connections to the Vault allowed for sending audit activities relating to the platform
Correct answer: C
Explanation
The correct answer is C because 'MaxConcurrentConnections' specifically sets the limit for concurrent connections associated with individual accounts via the PSM. Options A and B refer to the CPM and PSM respectively, but do not address account-specific limits. Option D pertains to audit activities and is unrelated to account connections.