CompTIA Network+ (N10-008) — Question 469
A technician is troubleshooting network connectivity from a wall jack. Readings from a multimeter indicate extremely low ohmic values instead of the rated impedance from the switchport. Which of the following is the MOST likely cause of this issue?
Answer options
- A. Incorrect transceivers
- B. Faulty LED
- C. Short circuit
- D. Upgraded OS version on switch
Correct answer: C
Explanation
The most likely cause of extremely low ohmic values is a short circuit, which can create a path of little to no resistance. The other options, such as incorrect transceivers or a faulty LED, would not typically result in such low measurements, nor would an upgraded OS on the switch affect the electrical characteristics being measured.