Troubleshooting Cisco Data Center Infrastructure (DCIT) — Question 101
A Cisco UCS C125 M5 server is integrated with Cisco UCS Manager using direct connect mode. The adapter for the server is reported as "inoperable" inside Cisco UCS Manager. Which action resolves the issue?
Answer options
- A. Reseat the adapter on the motherboard of the server.
- B. Use a port expander with the vNlC adapter.
- C. Match the adapter firmware to the Cisco UCS Manager version.
- D. Connect the network cable to pert 6 of the vNIC adapter.
Correct answer: C
Explanation
The correct answer is C because ensuring that the adapter firmware is compatible with the version of Cisco UCS Manager is crucial for proper operation. Options A and B may not address firmware compatibility issues, and option D does not resolve the inoperability caused by firmware mismatches.