Designing Cisco Data Center Infrastructure (DCID) — Question 101

An engineer must design the compute portion of a data center environment. The environment includes:
• direct-attach Fibre Channel storage array with four 32 G Fibre Channel ports per controller
• Cisco UCS B-series servers equipped with Cisco UCS IOM 2408 Fabric Extenders
• Cisco 6454 Fabric Interconnects

The fabric interconnects connect to the LAN via 100G ports, the SAN via 32 G Fibre Channel ports, and the IOM 2408 via 10 G ports. Which storage connectivity strategy must the engineer choose?

Answer options

Correct answer: C

Explanation

The correct answer is C, as it provides the required two-port PortChannel from each IOM to each fabric interconnect and four Fibre Channel links from each SAN controller to each fabric interconnect, aligning with the system's design specifications. Options A and B do not meet the connectivity requirements for the Fibre Channel links, while option D specifies a four-port PortChannel that does not match the two-port requirement for the IOM to fabric interconnect connection.