Check Point Certified Security Administrator (CCSA) R80 — Question 174
Where do we need to reset the SIC on a gateway object?
Answer options
- A. SmartDashboard > Edit Gateway Object > General Properties > Communication
- B. SmartUpdate > Edit Security Management Server Object > SIC
- C. SmartUpdate > Edit Gateway Object > Communication
- D. SmartDashboard > Edit Security Management Server Object > SIC
Correct answer: A
Explanation
The correct answer is A because the SIC reset must be done specifically within the General Properties section of the Gateway Object in SmartDashboard. Options B and D refer to Security Management Server Objects, which are not the correct objects for SIC resets related to gateways. Option C is also incorrect as it does not specify the correct properties section for the operation.